The probability is the direct output of the EPSS model, and conveys an overall sense of the threat of exploitation in the wild. The percentile measures the EPSS probability relative to all known EPSS scores. Note: This data is updated daily, relying on the latest available EPSS model version. Check out the EPSS documentation for more details.
In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.
Test your applicationsUpgrade Echo:latest linux-6.12 to version 6.12.107-1~deb12u1 or higher.
Note: Versions mentioned in the description apply only to the upstream linux-6.12 package and not the linux-6.12 package as distributed by Echo.
See How to fix? for Echo:latest relevant fixed versions and status.
In the Linux kernel, the following vulnerability has been resolved:
Input: synaptics-rmi4 - bound the F54 report size to the allocated buffer
rmi_f54_work() reads a diagnostics report from the device into f54->report_data, sizing the transfer with rmi_f54_get_report_size():
report_size = rmi_f54_get_report_size(f54);
...
for (i = 0; i < report_size; i += F54_REPORT_DATA_SIZE) {
int size = min(F54_REPORT_DATA_SIZE, report_size - i);
...
rmi_read_block(.., f54->report_data + i, size);
}
report_data is allocated once at probe from F54's own electrode counts (array3_size(f54->num_tx_electrodes, f54->num_rx_electrodes, sizeof(u16))), but rmi_f54_get_report_size() computes the size from drv_data->num_*_electrodes when those are set, i.e. from the F55 function's electrode counts. Both counts come straight from device queries (F54 and F55 each report up to 255 electrodes) and nothing constrains the F55 counts to the F54 ones.
A malicious or malfunctioning RMI4 device that reports larger F55 electrode counts than its F54 counts makes report_size exceed the allocation, so the read loop writes past report_data (and the V4L2 dequeue memcpy() then reads past it). On conforming hardware the F55 configured electrodes are a subset of the F54 physical electrodes, so report_size never exceeds the buffer and well-behaved devices are unaffected.
Record the allocation size and reject a report that does not fit, mirroring the existing zero-size check.