CVE-2026-80754 Affecting linux-6.12 package, versions <6.12.107-1~deb12u1


Severity

Recommended
low

Based on default assessment until relevant scores are available.

Threat Intelligence

EPSS
0.16% (6th percentile)

Do your applications use this vulnerable package?

In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.

Test your applications
  • Snyk IDSNYK-ECHOLATEST-LINUX612-19964455
  • published20 Sept 2026
  • disclosed3 Sept 2026

Introduced: 3 Sep 2026

NewCVE-2026-80754  (opens in a new tab)

How to fix?

Upgrade Echo:latest linux-6.12 to version 6.12.107-1~deb12u1 or higher.

NVD Description

Note: Versions mentioned in the description apply only to the upstream linux-6.12 package and not the linux-6.12 package as distributed by Echo. See How to fix? for Echo:latest relevant fixed versions and status.

In the Linux kernel, the following vulnerability has been resolved:

Input: synaptics-rmi4 - fix F55 transmitter electrode count typo

During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos.

This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses.

Fix the typos by correctly assigning the TX electrode counts.