The probability is the direct output of the EPSS model, and conveys an overall sense of the threat of exploitation in the wild. The percentile measures the EPSS probability relative to all known EPSS scores. Note: This data is updated daily, relying on the latest available EPSS model version. Check out the EPSS documentation for more details.
In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.
Test your applicationsThere is no fixed version for RHEL:10 rv.
Note: Versions mentioned in the description apply only to the upstream rv package and not the rv package as distributed by RHEL.
See How to fix? for RHEL:10 relevant fixed versions and status.
In the Linux kernel, the following vulnerability has been resolved:
block: fix race between wbt_enable_default and IO submission
When wbt_enable_default() is moved out of queue freezing in elevator_change(), it can cause the wbt inflight counter to become negative (-1), leading to hung tasks in the writeback path. Tasks get stuck in wbt_wait() because the counter is in an inconsistent state.
The issue occurs because wbt_enable_default() could race with IO submission, allowing the counter to be decremented before proper initialization. This manifests as:
rq_wait[0]: inflight: -1 has_waiters: True
rwb_enabled() checks the state, which can be updated exactly between wbt_wait() (rq_qos_throttle()) and wbt_track()(rq_qos_track()), then the inflight counter will become negative.
And results in hung task warnings like: task:kworker/u24:39 state:D stack:0 pid:14767 Call Trace: rq_qos_wait+0xb4/0x150 wbt_wait+0xa9/0x100 __rq_qos_throttle+0x24/0x40 blk_mq_submit_bio+0x672/0x7b0 ...
Fix this by:
Splitting wbt_enable_default() into:
Using wbt_init_enable_default() in blk_register_queue() to ensure proper initialization during queue registration
Move wbt_init() out of wbt_enable_default() which is only for enabling disabled wbt from bfq and iocost, and wbt_init() isn't needed. Then the original lock warning can be avoided.
Removing the ELEVATOR_FLAG_ENABLE_WBT_ON_EXIT flag and its handling code since it's no longer needed
This ensures WBT is properly initialized before any IO can be submitted, preventing the counter from going negative.