Improper Control of a Resource Through its Lifetime The advisory has been revoked - it doesn't affect any version of package rv  (opens in a new tab)


Threat Intelligence

EPSS
0.17% (6th percentile)

Do your applications use this vulnerable package?

In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.

Test your applications
  • Snyk IDSNYK-RHEL10-RV-21679835
  • published24 Oct 2026
  • disclosed16 Sept 2026

Introduced: 16 Sep 2026

CVE-2026-89929  (opens in a new tab)
CWE-664  (opens in a new tab)

Amendment

The Red Hat security team deemed this advisory irrelevant for RHEL:10.

NVD Description

Note: Versions mentioned in the description apply only to the upstream rv package and not the rv package as distributed by RHEL.

In the Linux kernel, the following vulnerability has been resolved:

KVM: nVM: Ensure INVVPID is emulated on the correct physical CPU

When emulating INVVPID, KVM executes INVVPID on the physical CPU using vpid02 (instead of the L1 assigned VPID), after doing some validations on the operands. However, it is possible that the physical CPU KVM executes INVVPID on is different from the CPU L2 is running on.

For example, in the following scenario:

  • L2 runs on CPU #1 and exits to L1 (vmx->nested.vmcs02.cpu=1)
  • L1 migrates to CPU #2 and executes INVVPID
  • KVM executes INVVPID on CPU #2
  • L1 migrates back to CPU #1 and runs L2 (vmx->nested.vmcs02.cpu=1)

The TLB entries on CPU #1 are never invalidated, because INVVPID was executed on CPU #2, and vmcs02 never ran on a different pCPU (i.e. vmx_vcpu_load_vmcs() will not request KVM_REQ_TLB_FLUSH).

Ensure that INVVPID is being executed on the same pCPU that L2 last ran on, and if not, fallback to clearing last_vpid=0 to trigger a full VPID flush on the next nested VM-Enter (as KVM will detect L1 using a different VPID for L2). If L2 ends up running on a different pCPU, KVM will flush the TLB anyway through vmx_vcpu_load_vmcs().