OS Command Injection Affecting plasma-workspace package, versions <4:5.10.5-0ubuntu1.1


Severity

Recommended
0.0
medium
0
10

Based on Ubuntu security rating.

Threat Intelligence

EPSS
0.78% (55th percentile)

Do your applications use this vulnerable package?

In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.

Test your applications
  • Snyk IDSNYK-UBUNTU1710-PLASMAWORKSPACE-290084
  • published7 Feb 2018
  • disclosed7 Feb 2018

Introduced: 7 Feb 2018

CVE-2018-6791  (opens in a new tab)
CWE-78  (opens in a new tab)

How to fix?

Upgrade Ubuntu:17.10 plasma-workspace to version 4:5.10.5-0ubuntu1.1 or higher.

NVD Description

Note: Versions mentioned in the description apply only to the upstream plasma-workspace package and not the plasma-workspace package as distributed by Ubuntu. See How to fix? for Ubuntu:17.10 relevant fixed versions and status.

An issue was discovered in soliduiserver/deviceserviceaction.cpp in KDE Plasma Workspace before 5.12.0. When a vfat thumbdrive that contains `` or $() in its volume label is plugged in and mounted through the device notifier, it's interpreted as a shell command, leading to a possibility of arbitrary command execution. An example of an offending volume label is "$(touch b)" -- this will create a file called b in the home folder.