Information Exposure Affecting org.apache.tomcat:tomcat-catalina package, versions [7.0.0,7.0.76) [8,8.0.42) [8.5.0,8.5.12) [9-alpha,9.0.0.M17)
Threat Intelligence
EPSS
0.36% (73rd
percentile)
Do your applications use this vulnerable package?
In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.
Test your applications- Snyk ID SNYK-JAVA-ORGAPACHETOMCAT-31421
- published 21 May 2017
- disclosed 11 Apr 2017
- credit Tomcat Security Team
Introduced: 11 Apr 2017
CVE-2017-5648 Open this link in a new tabOverview
org.apache.tomcat:tomcat-catalina
While investigating bug 60718, it was noticed that some calls to application listeners in Apache Tomcat 9.0.0.M1 to 9.0.0.M17, 8.5.0 to 8.5.11, 8.0.0.RC1 to 8.0.41, and 7.0.0 to 7.0.75 did not use the appropriate facade object. When running an untrusted application under a SecurityManager, it was therefore possible for that untrusted application to retain a reference to the request or response object and thereby access and/or modify information associated with another web application.
References
CVSS Scores
version 3.1