Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') Affecting vaultwarden package, versions <1.33.0


Severity

Recommended
0.0
high
0
10

CVSS assessment made by Snyk's Security Team. Learn more

Threat Intelligence

Exploit Maturity
Proof of Concept
EPSS
0.04% (12th percentile)

Do your applications use this vulnerable package?

In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.

Test your applications
  • Snyk IDSNYK-RUST-VAULTWARDEN-8663474
  • published28 Jan 2025
  • disclosed27 Jan 2025
  • creditElizarBatin

Introduced: 27 Jan 2025

CVE-2025-24364  (opens in a new tab)
CWE-74  (opens in a new tab)

How to fix?

Upgrade vaultwarden to version 1.33.0 or higher.

Overview

Affected versions of this package are vulnerable to Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') via the admin panel. An attacker with authenticated access can execute arbitrary commands by manipulating the mail agent settings to use a shell command and crafting a special favicon image embedded with commands, which are executed when sending a test email.