CVE-2022-48817 Affecting kernel-zfcpdump package, versions <5.14.21-150400.24.128.1


Severity

Recommended
0.0
medium
0
10

Based on SUSE Linux Enterprise Server security rating.

Threat Intelligence

EPSS
0.05% (18th percentile)

Do your applications use this vulnerable package?

In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.

Test your applications
  • Snyk IDSNYK-SLES154-KERNELZFCPDUMP-7691958
  • published16 Aug 2024
  • disclosed15 Aug 2024

Introduced: 15 Aug 2024

CVE-2022-48817  (opens in a new tab)

How to fix?

Upgrade SLES:15.4 kernel-zfcpdump to version 5.14.21-150400.24.128.1 or higher.

NVD Description

Note: Versions mentioned in the description apply only to the upstream kernel-zfcpdump package and not the kernel-zfcpdump package as distributed by SLES. See How to fix? for SLES:15.4 relevant fixed versions and status.

In the Linux kernel, the following vulnerability has been resolved:

net: dsa: ar9331: register the mdiobus under devres

As explained in commits: 74b6d7d13307 ("net: dsa: realtek: register the MDIO bus under devres") 5135e96a3dd2 ("net: dsa: don't allocate the slave_mii_bus using devres")

mdiobus_free() will panic when called from devm_mdiobus_free() <- devres_release_all() <- __device_release_driver(), and that mdiobus was not previously unregistered.

The ar9331 is an MDIO device, so the initial set of constraints that I thought would cause this (I2C or SPI buses which call ->remove on ->shutdown) do not apply. But there is one more which applies here.

If the DSA master itself is on a bus that calls ->remove from ->shutdown (like dpaa2-eth, which is on the fsl-mc bus), there is a device link between the switch and the DSA master, and device_links_unbind_consumers() will unbind the ar9331 switch driver on shutdown.

So the same treatment must be applied to all DSA switch drivers, which is: either use devres for both the mdiobus allocation and registration, or don't use devres at all.

The ar9331 driver doesn't have a complex code structure for mdiobus removal, so just replace of_mdiobus_register with the devres variant in order to be all-devres and ensure that we don't free a still-registered bus.

CVSS Scores

version 3.1