CVE-2026-90030 Affecting kernel-livepatch-6_4_0-150700_53_90-default package, versions <1-150700.15.3.1


Severity

Recommended
0.0
medium
0
10

Based on SUSE Linux Enterprise Server security rating.

Threat Intelligence

EPSS
0.16% (5th percentile)

Do your applications use this vulnerable package?

In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.

Test your applications
  • Snyk IDSNYK-SLES157-KERNELLIVEPATCH6401507005390DEFAULT-22237047
  • published5 Nov 2026
  • disclosed3 Nov 2026

Introduced: 3 Nov 2026

NewCVE-2026-90030  (opens in a new tab)

How to fix?

Upgrade SLES:15.7 kernel-livepatch-6_4_0-150700_53_90-default to version 1-150700.15.3.1 or higher.

NVD Description

Note: Versions mentioned in the description apply only to the upstream kernel-livepatch-6_4_0-150700_53_90-default package and not the kernel-livepatch-6_4_0-150700_53_90-default package as distributed by SLES. See How to fix? for SLES:15.7 relevant fixed versions and status.

In the Linux kernel, the following vulnerability has been resolved:

usb: dwc3: clear forceRM when issuing EndTransfer

The forceRM bit of the DEPCMD register controls the behavior of the EndTransfer command used to stop an active transfer. Older DWC3 programming guide revisions recommended setting forceRM=1 when issuing EndTransfer. Newer programming guide revisions recommend issuing EndTransfer with forceRM cleared.

With forceRM=1 on DWC_usb31 v2.00a and v2.10a controllers, a transfer aborted through the ep_dequeue path was observed to remain active after EndTransfer completion. A subsequent StartTransfer issued on the same endpoint triggered writes associated with the aborted transfer. This resulted in an SMMU fault because the transfer buffer had already been unmapped during EndTransfer command-completion cleanup.

Using forceRM=0 eliminates the issue. Although older DWC3 programming guide revisions recommended setting forceRM=1, no issues are known from using forceRM=0. Clear forceRM when issuing EndTransfer to provide consistent EndTransfer behavior and align with newer programming guide recommendations.