CVE-2026-89738 Affecting kernel-devel-nvidia package, versions <6.12.0-160100.7.1


Severity

Recommended
0.0
medium
0
10

Based on SUSE Linux Enterprise Server security rating.

Threat Intelligence

EPSS
0.19% (9th percentile)

Do your applications use this vulnerable package?

In a few clicks we can analyze your entire application and see what components are vulnerable in your application, and suggest you quick fixes.

Test your applications
  • Snyk IDSNYK-SLES1610-KERNELDEVELNVIDIA-22592149
  • published18 Nov 2026
  • disclosed9 Nov 2026

Introduced: 9 Nov 2026

NewCVE-2026-89738  (opens in a new tab)

How to fix?

Upgrade SLES:16.1.0 kernel-devel-nvidia to version 6.12.0-160100.7.1 or higher.

NVD Description

Note: Versions mentioned in the description apply only to the upstream kernel-devel-nvidia package and not the kernel-devel-nvidia package as distributed by SLES. See How to fix? for SLES:16.1.0 relevant fixed versions and status.

In the Linux kernel, the following vulnerability has been resolved:

usb: gadget: at91_udc: drain polled-VBUS timer/work before udc is freed

In polled-VBUS mode (board.vbus_pin && board.vbus_polled), probe arms a self-restarting cycle: at91_vbus_timer() schedules vbus_timer_work, and at91_vbus_timer_work() calls at91_vbus_update() and re-arms the timer via mod_timer(). Both recover the same udc through container_of and dereference it on every iteration.

Neither teardown path cancels this cycle. udc is devm-allocated, so it is freed after at91udc_remove() returns, and is likewise freed when probe fails and devres runs. A timer callback or work item that is pending or running at either point dereferences the freed udc.

Add at91_udc_shutdown_vbus_timer() and call it from at91udc_remove() and from the usb_add_gadget_udc() failure path in probe; the remaining probe error paths fail before the timer is armed. timer_shutdown_sync() waits for a running callback and clears timer->function, which makes the work handler's mod_timer() a permanent no-op; cancel_work_sync() then drains any pending or running work whose re-arm attempt now does nothing. The timer must be shut down first, since cancelling the work alone would let the timer re-queue it. The guard mirrors probe: in IRQ mode the timer and work_struct are never initialized.

This does not require a fault; a normal driver unbind can interleave with an already queued work item.

This issue was found by an in-house static analysis tool.

CVSS Base Scores